| Specification | Details |
|---|---|
| Lung technology | Internal Simulated Lung (ISL) — based on ASL 5000® Breathing Simulator technology |
| Resistance | 8 to 150 cmH2O/L/s |
| Compliance | 3 to 150 mL/cmH2O |
| Breath rate | Passive to 100 bpm |
| Patient effort | 0 to 50 cmH2O muscle pressure |
| Neural inspiratory time | 0.1 to 3.6 seconds |
| Maximum tidal volume | 900mL |
| PEEP | Holds PEEP greater than 20 cmH2O |
| Lung simulation | Independent left and right lung compliance; tracheal, left, and right bronchial resistance |
| Tetherless operation | Minimum 2 hours without wall power |
| Connectivity | Wireless or Ethernet connection to RespiSim® software |
| Patient age simulation | Adult and paediatric — 12 years and above |
| Airway access | Oral and nasal intubation — OPA, NPA, iGel, LMA, LT, ETT |
| Vascular access | IV and IO |
| CPR feedback | Real-time depth and rate feedback |
| BVM feedback | Real-time tidal volume, pressure, rate, and minute ventilation |
| Patient monitor | True-to-life monitor — ECG, EtCO2, SpO2, blood pressure, X-rays, CT scans |
| Ventilator compatibility | All ventilators — ICU to transport |
| Skin | 2-year manufacturer’s warranty |
| Operating gas | Compressed air recommended — 100% oxygen not recommended |
Aurora Respiratory Training Simulator
A high-fidelity respiratory training simulator with Internal Simulated Lung technology, real ventilator compatibility, and tetherless operation. Covers BVM, NIV, ICU ventilation, CPR, intubation, and ALS training.
- What makes Aurora different from a standard mannequin for ventilation training?
Aurora contains an Internal Simulated Lung based on ASL 5000 technology — meaning it breathes spontaneously, triggers real ventilators, responds to ventilator settings and alarms, and simulates a wide range of respiratory disease states just as a real patient would. - Can learners use their own real clinical equipment?
Yes. Aurora is compatible with any ventilator on the market, plus real bag-valve masks, CPAP, BiPAP, and all standard airway adjuncts — so learners train on the exact equipment they will use clinically. - What types of ventilation scenarios can be simulated?
Aurora supports pressure and volume control, SIMV, Pressure Support, ASV, PAV, CPAP, BiPAP, and non-invasive ventilation — as well as spontaneous breathing weaning scenarios, patient-ventilator dyssynchrony, air trapping, and lung-protective ventilation strategies. - Is it portable enough for multi-room and transport scenario training?
Yes. The tetherless capability provides at least 2 hours of operation without wall power, and the wireless software connection means Aurora can be moved between rooms or used in transport training scenarios without disrupting the simulation. - What training and support is included with purchase?
Every Aurora purchase includes a RespiSim LMS subscription for self-directed hardware and software learning. Additional on-site clinical consultation and extended warranty options are available separately.